Not all coatings are equal

The panels in the photo have both undergone 4,200 hours of cyclic corrosion testing according to ISO 12944-9 CX. Each panel had a different coating. A scribe was made in the paint beforehand to measure the corrosion that developed from it during the test. Despite both being properly blasted and having the same coating thickness, the difference in results is enormous.
How we carry out the ISO 12944-9 CX test at M2LAB
Step 1: The paint system is applied to blasted steel panels measuring 150 × 75 mm and at least 3 mm thick. Step 2: The test panels are stored for two weeks under standard laboratory conditions. Step 3: A scribe 2 mm wide is applied to the panels, cutting through the paint and any zinc layer. Step 4: The coating thickness and adhesion are measured.

- 3 days alternating 4 hours UV light and 4 hours water condensation
- 3 days salt spray test
- 1 day freezing cold at -20 °C
Evaluation criteria ISO 12944-9 CX
- Blistering (ISO 4628-2): 0
- Rusting (ISO 4628-3): Ri0
- Cracking (ISO 4628-4): 0 (S0)
- Flaking (ISO 4628-5): 0 (S0)
- Corrosion from scribe ≤ 3 mm (≤ 8 mm for high impact areas)
- Adhesion (ISO 4624): minimum adhesion strength of 5 MPa per measurement. 0% failure between steel and first layer, unless the minimum adhesion strength of 5 MPa is achieved.