According to FED-STD-791D Method 3007.2, corrosion-inhibiting products are assessed for water displacement and stability. M2LAB carried out this military test on Tectyl 800-D BF — with a fully positive assessment as the result.

Testing according to military standards

Corrosion-inhibiting materials are tested worldwide according to internationally recognised standards. M2LAB recently carried out a test on Tectyl 800-D BF in accordance with FED-STD-791D, Method 3007.2. This federal test standard is applied by US government agencies, including the Army, Navy and Air Force, for the assessment of lubricants and corrosion-inhibiting products.

Method 3007.2 in practice

In the video below, you can see part of Method 3007.2 in action: the test for water displacement and water stability. This test demonstrates how a corrosion-inhibiting product behaves when metal surfaces have already been in contact with water.

What is assessed according to Method 3007.2?

  • Water displacement The test determines whether the product can effectively displace water from a metal surface and leave a continuous protective film that prevents rust formation, even when the metal is already wet.
  • Water stability An assessment is made of whether the product remains stable in the presence of water and does not separate or lose its protective properties.
These properties are crucial for applications in which metal components are exposed to humid or maritime conditions.

The test procedure in brief

  • Steel test panels are blasted to create a uniform rough surface.
  • The panels are briefly immersed in distilled water.
  • They are then placed horizontally in the test oil and in a specially prepared oil-water emulsion.
  • The panels remain for one hour in a static climate chamber at 25°C and 50% relative humidity.
After completion, visual inspection takes place in accordance with the requirements of the standard.

Result: full approval

M2LAB carried out this military test on Tectyl 800-D BF, resulting in a full PASS. After inspection, no rust formation, discolouration or surface degradation was observed on the critical surfaces. The product therefore meets the strict requirements of FED-STD-791D Method 3007.2. Would you like to know whether your corrosion-inhibiting system meets international or military standards? Please feel free to get in touch to discuss the appropriate test strategy.

De Coating Nerd

“Waar ik ook ben, op mijn werk of als ik vrij ben, ik kijk naar alles waar een verflaagje op zit. Helemaal als er iets mis mee is. Roestplekken, blaasjes en afbladderende verf, daar word ik gelukkig van! Nou ja, gelukkig… dat is wat overdreven. Maar ik vind het machtig interessant. Wat een mazzel heb ik dan ook dat ik hier mijn beroep van heb mogen maken. De hele dag onderzoek doen aan verfsystemen, ge(poeder)coate voorwerpen en bedrijven helpen bij het verbeteren van hun product.”